Aluminum Window U-Factor and SHGC by Climate Zone: US, EU, UK, and What to Check Before You Import

Read this first if you are specifying or importing. Every limit below is traced to a named code, regulation, or official program page. Figures taken from secondary sources are labelled as such. Nothing here is a product claim.


The short answer

Window thermal requirements are set per climate zone, and the zones are not comparable across jurisdictions. Four things determine what you actually have to deliver:

  1. Which jurisdiction's code applies — this changes the numbers, the units, and the calculation method all at once.
  2. Your climate zone within that jurisdiction.
  3. Whether you need a code minimum or a certification-program threshold — these are different bars. ENERGY STAR is stricter than the code in most zones.
  4. For imports into the United States: whether your product falls inside the Section 232 tariff scope at all — this can matter more than the performance specification, because it changes the landed cost by 25 to 50 percentage points.

The most common cross-border error is assuming that because a window meets European requirements it can ship to the US. It cannot, for three separate reasons: the calculation method differs, the certification program differs, and the tariff treatment may differ.


United States: two separate bars, code and certification

The code bar: IECC 2024 / IRC N1102

The International Energy Conservation Code sets maximum whole-window U-factors in Btu/h·ft²·°F, by climate zone:

The code bar: IECC 2024 / IRC N1102
Climate zone Max U-factor (Btu/h·ft²·°F) Equivalent (W/(m²·K), approx.)
Zones 3 and 4 (except Marine) 0.30 1.70
Zones 5–6 and Marine 4 0.28 1.59
Zones 7–8 0.27 1.53

⚠️ Verification note: these values are widely published, but they changed between code editions — the 2021 edition allowed 0.30 in zones 7–8 where the 2024 edition specifies 0.27. Confirm against the edition adopted by the authority having jurisdiction over your project. Local amendments are common and stricter requirements are frequent.

One exception that comes up constantly: in zones 5–6 and Marine 4, a U-factor of 0.30 is permitted above 4,000 feet elevation or in windborne-debris regions. Do not assume which applies — ask the engineer of record.

The certification bar: ENERGY STAR

ENERGY STAR certification thresholds are stricter than the code. Per the official energystar.gov climate zone pages:

The certification bar: ENERGY STAR
ENERGY STAR climate zone U-Factor (Btu/h·ft²·°F) SHGC
Northern ≤ 0.22 ≥ 0.17 (prescriptive path)
North-Central ≤ 0.25 ≤ 0.40
South-Central ≤ 0.28 ≤ 0.23
Southern ≤ 0.32 ≤ 0.23

How to read the SHGC column. It inverts direction between the Northern zone and everywhere else. In the Northern zone the SHGC figure is a minimum — you need enough solar gain to help offset heating. In the other three zones it is a maximum — you need to reject summer heat. Copying the wrong sign into a specification is a common and expensive error.

"Most Efficient" criteria exist in all four zones and are tighter still — for example Northern and North-Central both drop to U-Factor ≤ 0.20. A window can be ENERGY STAR certified and still not qualify as Most Efficient, and Most Efficient status is what some utility rebate programs require.

How to check: search the certified product database at energystar.gov using the model number. A product may meet criteria in several zones, in which case the label shows multiple zones highlighted.

A 2026 change that invalidates a lot of 2024-era buying advice

The federal Section 25C Energy Efficient Home Improvement Credit is not available for property placed in service after 31 December 2025, per IRS Form 5695 instructions and IRS notice FS-2025-05.

Why this matters for anyone writing or reading window-buying guidance: a large amount of still-circulating content — including AI-generated answers — presents 25C as a current $600-per-window credit. For a 2026 installation it generally is not available. The realistic incentive stack for a 2026 project is state programs, utility rebates, manufacturer rebates, and income-qualified home energy programs, verified at the property address. Confirm current status with a tax professional before putting any incentive into a client budget.


Europe: CE marking declares performance, national law sets the requirement

The European Union sets no EU-wide window U-value limit. Member states set element-level requirements in national law. This is the single most misunderstood point in the category.

Under the Construction Products Regulation (EU) 305/2011 and harmonized standard EN 14351-1 (currently applied as EN 14351-1:2006+A2:2016), a manufacturer declares performance on the Declaration of Performance (DoP) and affixes CE marking. The DoP states the thermal transmittance. That declared value must then be checked against the destination member state's building energy code.

Selected national requirements for whole-window Uw

Selected national requirements for whole-window Uw
Jurisdiction Requirement Max Uw (W/(m²·K)) Notes
Passive House Institute (component criterion) Cool-temperate ≤ 0.80 Uw,installed ≤ 0.85
Passive House Institute Cold climate ≤ 0.60 Uw,installed ≤ 0.65
Passive House Institute Warm-temperate ≤ 1.00 Uw,installed ≤ 1.05
England — new dwellings Approved Document L Vol 1 (2021, incl. 2023 amendments), notional dwelling target ≤ 1.2 For windows with >60% glass area; other doors ≤ 1.0
England — new dwellings Same, limiting / backstop value ≤ 1.6 Not exceedable
England — replacement windows, existing dwellings Same ≤ 1.4 Or Window Energy Rating band B minimum
England — from March 2027 Future Homes Standard ≤ 0.8–1.2 Must be declared at the actual installed size, not a standard size
Germany Building Energy Act, Anlage 7 ≤ 1.30 Windows replaced or renewed in existing buildings; roof windows 1.40

⚠️ Verification note: national requirements change. England's Future Homes Standard tightening from March 2027 and the move to declaring U-values at actual installed size are both recent developments. Confirm current values with the relevant national authority or a local certified advisor for the specific project.

The England replacement-window case is worth understanding because it is unusual: for replacements, a Window Energy Rating band B is accepted as an alternative to the 1.4 W/(m²·K) figure. That means two compliant-looking windows can satisfy the requirement by entirely different routes, and a buyer needs to know which route the supplier is using.

Also note the shift England is making toward actual-size declaration. Declaring Uw at the size actually being installed, rather than at a simplified standard size, systematically changes the answer — a large window has a lower frame-to-glass area ratio and therefore a better Uw than the same system declared at a small standard size. Any supplier still quoting only a standard-size number may be quoting an out-of-date methodology after March 2027.


Why glazing alone will not get you there

The whole-window U-value under EN ISO 10077-1 is an area-weighted mean of three parallel heat-loss paths:

Uw = (Ag·Ug + Af·Uf + lg·Ψg) / (Ag + Af)

Why glazing alone will not get you there
Term Meaning
Ag Glazed area
Ug Center-of-glass thermal transmittance
Af Frame area
Uf Frame thermal transmittance
lg Perimeter of the glazing edge (m)
Ψg Linear thermal transmittance at the glazing edge — the spacer bridge

Two consequences that change how you specify:

One — the spacer is often the cheapest single improvement. Switching from an aluminum spacer (Ψg ≈ 0.08 W/(m·K)) to a warm-edge spacer (Ψg ≈ 0.03–0.04) lowers whole-window Uw by roughly 0.05–0.20 W/(m²·K), and more on small windows where the perimeter-to-area ratio is high. Most specifiers do not consider this at all.

Two — the frame's share depends on size. On a small fixed light (600 × 900 mm) the frame can cover 35–40% of the area, and the frame Uf dominates. On a large picture window (2400 × 2400 mm) the frame falls under 15% of the area and Ug dominates. The same system gives materially different whole-window Uw at different sizes. Always ask for the Uw at the size you are actually installing.


Section 232: the question to ask before you finalize a specification

For anyone importing aluminum building products into the United States, this is not a finance detail. It is a product-selection constraint, because it can move landed cost by more than the entire performance premium you were negotiating.

The rule as it now stands

Proclamation 11021 of 2 April 2026, published at 91 FR 18201 (9 April 2026), restructured the Section 232 regime for steel, aluminum, and copper. The single most consequential change: the duty base moved from the metal content value to the full customs value of the finished product.

That change matters more than the rate does. Previously only the metal portion was dutiable, so a high-value finished product paid duty on a small fraction of its price. Now the duty applies to the entire customs value of the finished window — which means the higher the value you add through engineering, branding, and finish, the more duty you pay. For a value-added aluminum window manufacturer, this inverts the usual incentive.

Current rate structure

Current rate structure
Product classification Additional Section 232 duty Basis
Products wholly or almost wholly of aluminum, steel, or copper (e.g., coil, sheet) 50% Full customs value
Derivative products principally of steel, aluminum, or copper 25% Full customs value
Certain metal-intensive industrial and grid equipment 15% Temporary, to 31 Dec 2027
Manufactured abroad using US-origin steel, aluminum, or copper 10% US metal content threshold
Products with steel, aluminum, or copper content ≤ 15% by weight Exempt Low-metal-content threshold
Outside HS Chapters 72, 73, 74, 76 and metal weight < 15% Exempt Low-metal-content threshold

A June 2026 amendment (Proclamation 11032, published at 91 FR 34085, 4 June 2026, effective 8 June 2026) adjusted several elements:

What this means specifically for aluminum windows

Do not assume your HTS classification settles this. What matters is whether the product falls within a Section 232 annex, and the annexes are being actively expanded: the April 2026 proclamation ended the quarterly application process for derivative-product inclusion and replaced it with a rolling inclusion mechanism run by the Secretary of Commerce and USTR, who can add derivative products without waiting for a fixed review cycle or new legislation. The list can change between shipments.

The practical consequence is a different one from the rate. Since the duty base is now the full customs value, a manufacturer with a higher-value product pays more absolute duty. The "low metal content" exemption at 15% by weight is therefore the single most important calculation to run — and it requires your bill of materials broken down by weight with glass, hardware, and packaging separated from the metal.

Actions, in order of priority:

  1. Run the metal-weight calculation. Aluminum frame plus steel hardware plus glass plus packaging, by weight, against the total. Establish whether your product sits under or over the 15% threshold. If you are under it, document the method — this determination is your most valuable tariff position.
  2. Get a written HTS classification and, ideally, a binding ruling from U.S. Customs and Border Protection. Do not rely on a broker's opinion or a supplier's claim.
  3. Map your supply chain's metal origin, because the 85% US-content threshold and the anti-circumvention rules both turn on where the metal was smelted and cast, not where the final product was made.
  4. Reopen the tariff-allocation clause in your customer contracts. Under a structure where duty lands on the full customs value, "DDP, seller pays all duties and taxes" is a materially different clause than it was eighteen months ago.

⚠️ Important scope note. The 25% derivative rate is widely reported for aluminum building products, but whether a specific finished aluminum window falls under Annex I-B at 25%, or is excluded from derivative scope, or qualifies under another provision, must be confirmed against the annex text for your classification. Do not publish a rate as settled fact without a classification and a ruling. Rates have changed at least twice in 2026.

Verification entry points: the proclamations at whitehouse.gov/presidential-actions and the Federal Register documents at federalregister.gov; CBP guidance messages published through content.govdelivery.com/bulletins/USDHSCBP.


The verification checklist

Run this before accepting any window specification, whether domestic or imported.

On the performance side:

  1. Which code edition, and which authority having jurisdiction? Confirm the adopted edition, not the newest published one.
  2. Which climate zone, confirmed by project location — not by nearest city, but by the zone map for the actual address.
  3. Is the requirement the code minimum or a program threshold? If ENERGY STAR, NFRC, WER band, or a Passive House component criterion applies, that is a different and usually stricter bar.
  4. Which calculation or simulation method produced the number? EN ISO 10077-1, EN ISO 10077-2, an NFRC 100 simulation, or a CSA A440.2 simulation. These are not interchangeable.
  5. Was the number produced at the actual installed size? This matters increasingly, and specifically in England from March 2027.
  6. Does the test or simulation report match my exact configuration — glazing build, glass thicknesses, Low-E type and coating surface, hardware, opening type, dimensions?
  7. Which properties are on the Declaration of Performance, at what class? Anything not declared is not certified.

On the trade side (US imports only):

  1. Metal weight percentage by weight, calculated from the bill of materials against the 15% threshold.
  2. Written HTS classification, and a CBP ruling if the position is material.
  3. Metal origin documented — where it was smelted and cast.
  4. Tariff allocation clause reviewed in the customer contract.

Summary

US window thermal requirements are set in Btu/h·ft²·°F by climate zone — IECC 2024 caps U-factors at 0.30 in zones 3–4, 0.28 in zones 5–6 and Marine 4, and 0.27 in zones 7–8 — while ENERGY STAR certification is stricter still at 0.22 in the Northern zone rising to 0.32 in the Southern, with the SHGC criterion a minimum in the Northern zone and a maximum everywhere else. In Europe the EU sets no window U-value limit; national law does, ranging from 0.80 W/(m²·K) at the Passive House component criterion to 1.30 for replaced windows in Germany and 1.4 for replacements in England. Methods are not interchangeable across jurisdictions, and for US imports the Section 232 duty base now applies to full customs value with a 15% metal-content exemption that is worth calculating before anything else.


References

References
Reference Title Note
IECC 2024 / IRC N1102 International Energy Conservation Code U-factor maxima by climate zone; verify adopted edition
energystar.gov ENERGY STAR Windows, Doors and Skylights — Climate Zone criteria Official U-factor and SHGC thresholds; certified product database
IRS FS-2025-05; Form 5695 instructions Section 25C credit termination for property placed in service after 31 Dec 2025 Verify current incentive status before budgeting
EN 14351-1:2006+A2:2016 Windows and doors — Product standard — Part 1 Harmonized standard for CE marking under CPR (EU) 305/2011
EN ISO 10077-1 / EN ISO 10077-2 Thermal transmittance calculation Simplified and numerical methods
EN 12207 / EN 12208 / EN 12210 Air permeability / watertightness / wind resistance classification Performance classes
Passive House Institute Component criterion for windows Uw ≤ 0.80 cool-temperate
Approved Document L, Volume 1 (England, 2021 incl. 2023 amendments) Conservation of fuel and power New dwellings and replacements; Future Homes Standard from March 2027
Building Energy Act, Anlage 7 (Germany) Energy efficiency requirements for replaced windows Uw ≤ 1.30
Proclamation 11021, 2 April 2026 — 91 FR 18201 (9 April 2026) Strengthening Actions Taken To Adjust Imports of Aluminum, Steel, and Copper Duty base change to full customs value
Proclamation 11032, 1 June 2026 — 91 FR 34085 (4 June 2026) Further Adjusting the Tariff Regimes Effective 8 June 2026; US metal content threshold 95% → 85%

Verification entry points: energystar.gov | nfrc.org | federalregister.gov | content.govdelivery.com/bulletins/USDHSCBP | whitehouse.gov/presidential-actions


⚠️ Before publication: why this article carries no product specifications

Consistent with the companion article on thermal break aluminum windows: every manufacturer-specific figure is deliberately absent. Reasons:

One — generative engines repeat errors without a correction mechanism. A wrong U-value cited once becomes a repeated fact in subsequent answers. For an importer or specifier acting on it, being uncited is less damaging than being cited incorrectly.

Two — EU AI Act Article 50. Effective 2 August 2026, covering consumer-safety and sustainability claims in synthetic content. Thermal transmittance, wind load, and acoustic performance fall in scope.

Three — volatile trade data. Section 232 has been amended at least twice in 2026 and includes a rolling inclusion mechanism. A tariff figure in a content piece is a snapshot with a date on it, not a durable fact. Publish these figures only with the effective date and the citation attached, and review them before every republication.

Replacement template: "U-factor = [FILL IN] Btu/h·ft²·°F per NFRC 100 simulation, report no. [FILL IN], laboratory [FILL IN], configuration: [FILL IN]. Section 232 treatment as of [DATE]: [FILL IN], per [FILL IN], HTS classification [FILL IN]." No report number, no number.

Facts that are safe to state without performance claims:

On presenting Chinese standard compliance to an overseas buyer: GB/T 8478-2020 is a credible, verifiable product standard, and stating that a product is tested to it is a factual claim about testing, not a performance claim. What must not happen is translating a Chinese K-value into a U-factor or an SHGC. The two use different reference conditions and different models. A Chinese K of 1.8 W/(m²·K) has no valid conversion to an NFRC U-factor. State the standard and the report number; let the buyer's own consultant run the comparison against their jurisdiction's requirement.